{"id":2020,"date":"2021-10-05T13:03:17","date_gmt":"2021-10-05T16:03:17","guid":{"rendered":"https:\/\/nuevocindeca.quimica.unlp.edu.ar\/?page_id=2020"},"modified":"2022-01-12T11:07:19","modified_gmt":"2022-01-12T14:07:19","slug":"servicio-de-microscopia-electronica-de-barrido-y-microanalisis","status":"publish","type":"page","link":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/servicio-de-microscopia-electronica-de-barrido-y-microanalisis\/","title":{"rendered":"SERVICIO DE MICROSCOP\u00cdA ELECTR\u00d3NICA DE BARRIDO Y MICROAN\u00c1LISIS"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"2020\" class=\"elementor elementor-2020\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9616ddb elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9616ddb\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-33a43cd\" data-id=\"33a43cd\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3c00a13 elementor-widget elementor-widget-text-editor\" data-id=\"3c00a13\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"color: #000000;\"><strong>PRINCIPIOS DE LA T\u00c9CNICA<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>El microscopio electr\u00f3nico de barrido (SEM) es un instrumento que permite la observaci\u00f3n y caracterizaci\u00f3n superficial de materiales inorg\u00e1nicos y org\u00e1nicos.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>El principio del SEM consiste en la emisi\u00f3n termoi\u00f3nica de un haz de electrones que bombardea la superficie de la muestra generando distintos tipos de fen\u00f3menos. Estas se\u00f1ales que se generan en la muestra son la que nos dan la informaci\u00f3n morfol\u00f3gica o composicional del material analizado. <\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>El sistema de microan\u00e1lisis EDAX permite la realizaci\u00f3n de r\u00e1pidos an\u00e1lisis qu\u00edmicos de elementos de n\u00famero at\u00f3mico Z mayor que 5 (B) y concentraciones superiores a 0,5 wt %.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Las principales utilidades del SEM son la alta resoluci\u00f3n, la gran profundidad de foco que le da apariencia tridimensional a las im\u00e1genes y la sencilla preparaci\u00f3n de las muestras. La t\u00e9cnica ha sido perfeccionada con las facilidades derivadas de la digitalizaci\u00f3n y tratamiento de las im\u00e1genes.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Mediante la aplicaci\u00f3n conjunta de ambas t\u00e9cnicas (SEM-EDAX) es posible obtener la distribuci\u00f3n de los elementos qu\u00edmicos seleccionados en \u00e1reas definidas de inter\u00e9s.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>\u00a0<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Equipamiento<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>El Servicio cuenta con un microscopio electr\u00f3nico de barrido marca Philips SEM 505, con capacidad anal\u00edtica a trav\u00e9s del Sistema de Microsonda EDAX DX APOLLO X para an\u00e1lisis cualitativo\/cuantitativo.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Un metalizador Balzers SCD 030, que por el m\u00e9todo de sputtering permite realizar d\u00e9p\u00f3sitos delgados de Au, Au-Pd, Cr, Ni, y Cu.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Un vibrador ultras\u00f3nico para la dispersi\u00f3n de part\u00edculas y limpieza de superficies.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>\u00a0<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>PRINCIPALES APLICACIONES<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Geolog\u00eda: Estudio morfol\u00f3gico\/estructural y an\u00e1lisis qu\u00edmico de las muestras.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Materiales: Cer\u00e1micos, Semiconductores, Pol\u00edmeros, etc. Estudios de composici\u00f3n y caracter\u00edsticas granulom\u00e9tricas.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Metalurgia: An\u00e1lisis de falla, caracter\u00edsticas texturales y microan\u00e1lisis qu\u00edmico.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Odontolog\u00eda, Medicina, Biolog\u00eda: Estudios morfol\u00f3gicos y qu\u00edmicos.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Paleontolog\u00eda y Arqueolog\u00eda: Caracterizaci\u00f3n de aspectos morfol\u00f3gicos y de composici\u00f3n qu\u00edmica.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Control de Calidad: Seguimiento de procesos tanto morfol\u00f3gico como composicional.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Peritajes: Estudios de muestras de cualquiera de las \u00e1reas antes mencionadas.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>\u00a0<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>ES RECOMENDABLE, PREVIO A LA SOLICITUD DEL TURNO, ENVIAR UN CORREO ELECTR\u00d3NICO A LA DIRECCI\u00d3N DEL LABORATORIO (mas@quimica.unlp.edu.ar)\u00a0<\/strong><\/span><strong style=\"color: #000000; font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-size: 1rem;\">PARA CONSULTAR O INFORMAR SOBRE QU\u00c9 TIPO DE ESTUDIOS SE QUIEREN REALIZAR, N\u00daMERO DE MUESTRAS A ANALIZAR Y OTROS DETALLES, LO QUE RESULTAR\u00c1 \u00daTIL AL MOMENTO DE ESTIMAR EL TIEMPO DEL TURNO DEL SERVICIO Y POSIBILIDADES DEL MISMO.<\/strong><\/p><ol><li><span style=\"color: #000000;\"><strong> Duraci\u00f3n de los turnos: los turnos otorgados tienen una duraci\u00f3n m\u00ednima de 1 hora y m\u00e1xima de hasta 2 horas.<\/strong><\/span><\/li><li><span style=\"color: #000000;\"><strong> Confirmaci\u00f3n de los turnos: los turnos caducan en caso de no recibirse una confirmaci\u00f3n 3 d\u00edas h\u00e1biles antes de la fecha reservada. Para TODOS los usuarios la fracci\u00f3n m\u00ednima de tiempo facturada es de una hora.<\/strong><\/span><\/li><li><span style=\"color: #000000;\"><strong> Presencia del usuario: en el momento de observaci\u00f3n de las muestras es necesaria la presencia del usuario a fin de optimizar el tiempo del turno y los resultados de la medici\u00f3n.<\/strong><\/span><\/li><\/ol><p><span style=\"color: #000000;\"><strong>Puntualidad:<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Se tolerar\u00e1 hasta 15 minutos de demora en la llegada a los turnos asignados y confirmados, a partir de ese momento se comenzar\u00e1 a cobrar el servicio como hora\/uso del equipo.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Ingreso al laboratorio:<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Por razones de seguridad, no est\u00e1 permitido el ingreso de m\u00e1s de tres personas (adem\u00e1s del operador) en la sala del microscopio.<\/strong><\/span><\/p><p><span style=\"color: #000000;\"><strong>Muestras: <\/strong><\/span><\/p><ol><li><span style=\"color: #000000;\"><strong> En caso de necesitar una preparaci\u00f3n y\/o recubrimiento conductor de las muestras, el usuario (local o externo) deber\u00e1 traerlas al laboratorio con 1 d\u00eda de anticipaci\u00f3n, acordando previamente la fecha y horario con la persona a cargo, preferentemente mediante un correo electr\u00f3nico (mas@quimica.unlp.edu.ar), o por tel\u00e9fono (0211-4220288 int. 103).<\/strong><\/span><\/li><li><span style=\"color: #000000;\"><strong> No se trabajar\u00e1 con muestras nocivas para la salud, por lo tanto se solicitar\u00e1 al usuario que complete un formulario indicando que la muestra no es t\u00f3xica.<\/strong><\/span><\/li><li><span style=\"color: #000000;\"><strong> Las muestras que sean porosas y\/o contengan residuos vol\u00e1tiles deber\u00e1n prepararse adecuadamente, debiendo estar limpias y secas antes de ser introducidas en la metalizadora o en la c\u00e1mara del SEM.<\/strong><\/span><\/li><li><span style=\"color: #000000;\"><strong> En el caso que el operador considere que la muestra podr\u00eda ser perjudicial para los equipos, no ingresar\u00e1 la misma en la metalizadora o microscopio.<\/strong><\/span><\/li><\/ol>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>PRINCIPIOS DE LA T\u00c9CNICA El microscopio electr\u00f3nico de barrido (SEM) es un instrumento que permite la observaci\u00f3n y caracterizaci\u00f3n superficial de materiales inorg\u00e1nicos y org\u00e1nicos. El principio del SEM consiste en la emisi\u00f3n termoi\u00f3nica de un haz de electrones que bombardea la superficie de la muestra generando distintos tipos de fen\u00f3menos. Estas se\u00f1ales que se &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/servicio-de-microscopia-electronica-de-barrido-y-microanalisis\/\" class=\"more-link\">Segu\u00ed leyendo<span class=\"screen-reader-text\"> &#8220;SERVICIO DE MICROSCOP\u00cdA ELECTR\u00d3NICA DE BARRIDO Y MICROAN\u00c1LISIS&#8221;<\/span><\/a><\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"_links":{"self":[{"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/pages\/2020"}],"collection":[{"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/comments?post=2020"}],"version-history":[{"count":7,"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/pages\/2020\/revisions"}],"predecessor-version":[{"id":4962,"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/pages\/2020\/revisions\/4962"}],"wp:attachment":[{"href":"https:\/\/cindeca.quimica.unlp.edu.ar\/index.php\/wp-json\/wp\/v2\/media?parent=2020"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}